Movable Tiny Home Inspection Stages
Each segment of video must include a close up of VIN label
Stage 1 – Trailer Frame
- Axles and tires
- Brakes on each Axle
- Length & width of frame
Stage 2 – Frame
- Connection to trailer mounts
- All hurricane straps & headers
- Size of dimensional lumber or gauge of steel
- Nailing pattern on sheathing
Note: A Partial inspection of the house wrap, if used, prior to siding and a partial inspection of underlayment prior to roofing shall be required.
Stage 3 – All Trades
- Rough plumbing
- Rough electrical
- HVAC system
(This may be divided into 2 separate inspections.)
Stage 4 – Insulation
- Windows (type and U Value)
- Exterior door
- R value of Insulation (floor, walls, ceiling)
Stage 5 – Final
- Safety items such as smoke detector and secondary egress.
- Final plumbing such as traps and Air Admittance valves
- Final electrical such as GFIC outlets and breaker sizes,
Note: Stages 1, 2, & 3 can be combined as long as everything can be seen (anchor points, hurricane straps, etc…) A separate partial inspection for anything that might be covered up will be necessary.
Vehicle Conversions and Rehab Inspection Stages
Each segment of video must include a close up of VIN label
Stage 1 – All Trades
- Rough plumbing
- Rough electrical
- HVAC system
(This may be divided into 2 separate inspections.)
Stage 2 – Insulation
- Windows (if replaced) (type and U Value)
- Exterior door (If replaced)
- R value of Insulation (floor, walls, ceiling)
Stage 3 – Final
- Safety items such as smoke detector and secondary egress.
- Final plumbing such as traps and Air Admittance valves
- Final electrical such as GFIC outlets and breaker sizes,
Note: A separate partial inspection for anything that might be covered up will be necessary.